Catalog
UL 1007 Hook-up Wire
 
Product Description:
”“UL file NO. E55218
”“Rated temperature: 80¢J
”“Rated voltage: 300V
”“Reference standard: UL 758, UL1581 & CSA NO-127-99
”“Tinned or bare, stranded or solid copper conductor, 32-16 AWG
”“Colour-coded lead free PVC insulation
”“Passes UL VW-1 & CSA FT1 vertical flame test
”“Application:Internal wiring in electric & electric equipment.

Type Conductor AWG Conductor No./mm Conductor Dia./mm Insulation Avg. Thick/mm Insulation Nom. Dia./mm Jacket Avg. Thick/mm Maximum Conductor Resistance at 20¢J(£[/km)
UL 1007 16 16 65/0.16 1.49 0.38 2.50 14.60
UL 1007 18 18 34/0.18 1.18 0.38 2.10 23.20
UL 1007 20 20 21/0.18 0.94 0.38 1.90 36.70
UL 1007 22 22 7/0.26 0.76 0.38 1.70 59.40
UL 1007 24 24 7/0.20 0.61 0.38 1.50 94.20
UL 1007 26 26 7/0.16 0.48 0.38 1.35 150.00
UL 1007 28 28 7/0.127 0.38 0.38 1.20 239.00
UL 1007 30 30 7/0.10 0.30 0.38 1.10 381.00